TRENDMICRONS is a thickness
measurement and control system, designed for measuring the basis weight
of the calendared flat foil.
TRENDMICRONS system is designed for the contact less
measurement of the basis weight (= THICKNESS * SPECIFIC WEIGHT) of
foils, layers or tubes made of paper, rubber, plastic, metal, glass and
other materials or also of coating layers on films and textiles. The
cross profile is recorded by a transmission measuring sensor mounted in a
scanner traveling continuously back and forth across the material
web.
The salient features
are:
Measurement with logging
the data
Measurement without logging the data
- Parameter settings for any product could be
viewed, added, edited or deleted after login.
- Calibration curve can be modified / configured
and downloaded to the controller PLC or uploaded from plc only after
login.
- Auto and manual zero calibration
- User configurable correction
factor.
- All the trends and bell curve can be viewed on
line, or from current archive or from the selected monthly
archive.
- Trends of
thickness of the film in microns for three
consecutive scans along with the average, minimum, maximum thickness
values.
- Trends of
thickness of the film for a selected
scan
- Trends of the sliding average
thickness with minimum, maximum, average
values of the thickness at any
position.
- Trends of
thickness of the film along the left,
center and right zone of the roll width.
- Trends of
thickness of the film along the length and
width of the roll
- Trends of
thickness of the film at a specified
position along the length (m)
- Bell curve of deviation
in thickness of the roll
vs quantity (number)
- Database management.
- Statistics and report generation –
- Roll report,
- Shift report,
- Order and reject report
- Status of PLC inputs and outputs is
displayed.
- Alarms.
- Historical data for month and year
selectable for viewing.
|